3100 MMP CAP
GSI 3100 MMP Gauge

MMP is a new gauge recently introduced to the market. It is the third generation
of the CAP product line.
The MMP can physically install within any tank up to 20 feet (6m) in height
(UST, AST, Rail Car, Tank trucks, Bullet tanks, Cylinder Tanks, etc.). It is
simply not just another gauge, it is truly unique.
Consider a probe that is nothing but stainless steel pipe, with no sensitive
elements in contact with liquid media and No Moving Parts. Contemplate a probe
with custody transfer level accuracy (±1mm) working equally well with both
liquefied gases and liquids. Bear in mind this probe provides multi-point spot
temperature and average product temperature measurements. Think about a probe
that can measure water level with the same millimeter accuracy as liquid level.
The MMP provides for strapping tables and API/ISO volume calculations in the
transmitter head, digital MODBUS RTU protocol via RS-485 line and up to two
fully configurable 4-20 mA outputs assignable to any chosen (measured) value.
Finally mull over the fact that the probe is low in cost.
However, the list of advantages is far from being complete yet. MMP
automatically performs self-calibration during its operation; it has
capabilities of incorporating up to 400 points of strapping table directly into
the head as MODBUS registers. The temperature measurements are all based on
Class A or optional DIN standard, 4-wire, 100Ohm, platinum RTDs. The MMP can
output level and volume values in metric, English-Fractional, or English-Decimal
units directly from the head and is designed as Intrinsically Safe instrument
with extremely low power consumption (ideal for alternative powering and/or
remote monitoring applications).
Options include: number of temperature sensors, water measurement, level
accuracy (process – custody transfer), analog outputs, and mounting hardware
(UST, AST, Rail cars, Tank trucks, Bullet tanks, Cylinder tanks, etc.). Thus,
the ability to configure a probe to meet your performance needs and budget.
For LPG/LNG applications, the MMP includes an optional pressure measurement with
corresponding API/ISO calculations (amount of product in the gaseous space). In
addition to standard volume output, the density entry will allow liquid mass and
total mass calculations.
MMP is suitable to any dielectric, low viscosity liquid.
If you are liquid gas terminal or a light petroleum storage terminal operator -
consider this trouble free rigid and accurate instrument. It will provide you
more accuracy and reliability than one would expect from a normal tank gauge.